home *** CD-ROM | disk | FTP | other *** search
/ Shareware Overload Trio 2 / Shareware Overload Trio Volume 2 (Chestnut CD-ROM).ISO / dir26 / med9410o.zip / M94A2733.TXT < prev    next >
Text File  |  1994-10-25  |  3KB  |  48 lines

  1.        Document 2733
  2.  DOCN  M94A2733
  3.  TI    Performance of a new commercial test to measure HIV p24 antigen
  4.        utilizing acid dissociation.
  5.  DT    9412
  6.  AU    Sherlock CH; Karakas L; Craib KJ; University of British Columbia, St
  7.        Paul's Hospital, BC Centre for; Excellence in HIV/AIDS, Vancouver,
  8.        Canada.
  9.  SO    Int Conf AIDS. 1994 Aug 7-12;10(1):237 (abstract no. PB0376). Unique
  10.        Identifier : AIDSLINE ICA10/94369842
  11.  AB    OBJECTIVE: To assess the performance of a new HIV p24 antigen ELISA
  12.        (Coulter Corporation) and to compare this with the test of record in
  13.        North America (Abbott HIVAG-1). METHODS: 500 banked frozen sera were
  14.        selected from patients who were HIV antibody (ab) and HIVAG-1 positive.
  15.        200 sera were selected from HIVAb negative patients with no risks for
  16.        HIV infection. All sera were tested by Coulter HIV-1 p24 antigen assay
  17.        (C-p24) both before and after acid dissociation by the Coulter ICD Prep
  18.        Kit (ICD). All repeat positives were neutralized with Coulter's p24
  19.        neutralization assay (C-neut). Those that did not neutralize were called
  20.        negative. All Coulter tests were quantified in pg/ml; only 56 sera were
  21.        quantified by HIVAG-1. RESULTS: Of 500 HIVAG-1 positive sera, 423 (85%)
  22.        repeated C-p24 positive; of these, 405 were C-neut positive. After ICD,
  23.        497 (99.4%) repeated positive; all were C-neut positive. 2 of the 3 ICD
  24.        C-neut negatives were also C-p24 negative; 1 was low positive. Of the
  25.        200 HIV Ab negative sera, all were negative by both C-p24 and after ICD.
  26.        If Coulter ICD is taken as the test of reference, the C-p24 is 82%
  27.        sensitive and 99.5% specific. If HIVAG-1 is the test of reference, the
  28.        sensitivity of C-p24 is 81% and of ICD is 99.4%. The correlation
  29.        coefficient (r) between both C-p24 runs was 0.97, also for both ICD
  30.        runs. The correlation coefficient between C-p24 and HIVAG-1 on 56
  31.        quantified sera was 0.86 but the C-p24 concentrations were significantly
  32.        higher than the HIVAG-1 concentrations (ratio 1.4;p < .001, paired t
  33.        test). The ratio of mean ICD concentrations to mean C-p24 concentrations
  34.        was 5.8. DISCUSSION AND CONCLUSIONS: There would be little merit in
  35.        using C-p24 since its sensitivity is low compared with its own ICD
  36.        performance and with HIVAG-1. Coulter ICD results show excellent
  37.        sensitivity, specificity and reproducibility with mean p24
  38.        concentrations 5.8 times those with C-p24.
  39.  DE    Antigen-Antibody Complex/IMMUNOLOGY  Comparative Study  Enzyme-Linked
  40.        Immunosorbent Assay/*METHODS  Human  HIV Core Protein p24/*BLOOD  HIV
  41.        Seronegativity/IMMUNOLOGY  HIV Seropositivity/*DIAGNOSIS/IMMUNOLOGY
  42.        HIV-1/*IMMUNOLOGY  Predictive Value of Tests  Reproducibility of Results
  43.        MEETING ABSTRACT
  44.  
  45.        SOURCE: National Library of Medicine.  NOTICE: This material may be
  46.        protected by Copyright Law (Title 17, U.S.Code).
  47.  
  48.